DOORS FOR INSTALLATION IN CORRIDORS
SCOPE OF DOORS FOR INSTALLATION IN CORRIDORS
These doors are used only because the normal corner frame is not suitable for the fixing it on flush walls like in corridors and a frame of different shape must be used. This type of installation is also available in the fire rated version with specific certificates.
DESCRIPTION OF DOORS FOR INSTALLATION IN CORRIDORS
Construction like the handed doors, see the corresponding description in section “HANDED DOORS / Description / EI2 60 / EI2 120 / multipurpose (depending on the type chosen)”, but with frame having even rest on 3 sides of galvanized steel profile thickness 1,5 mm and fixing plates, painted with epoxy-polyester powders in the same RAL tone like the leaves. Expansion screws for fixing to the wall excluded.
DRAWINGS OF DOORS FOR INSTALLATION IN CORRIDORS


HORIZONTAL SECTION 1 LEAF


HORIZONTAL SECTION 2 LEAVES


VERTICAL SECTION

DIMENSIONS, ORDERS, NOTES
In the order indicate the dimensions of the real opening Lr x Hr = from wall to wall in width and from the finished floor to the ceiling for height. The external frame dimensions (all out) will be less as the tolerance space between frame and wall will be factory deducted. Following the tables of the doors of standard dimensions. Bigger or smaller dimensions can be ordered, if in the fire rated version the dimensions of the doors, glasses and their distance from the edges have to be within those allowed by the chosen certificate.
TABLE OF STANDARD DIMENSIONS 1 LEAF


TABLE OF STANDARD DIMENSIONS 2 LEAVES

OPTIONAL ACCESSORIES
Optional accessories are the same to those listed in the section “HANDED DOORS / Optional accessories”. The rubber gasket for frame JF4 cannot be installed on frames of this type and neither sound reduction kits.